com.ibm.di.api.local
Interface AssemblyLine

All Known Implementing Classes:
AssemblyLineImpl

public interface AssemblyLine

Represents an AssemblyLine instance.


Method Summary
 void addListener(AssemblyLineListener listener, boolean getLogs, boolean getEntryOnEachCycle)
          Register a listener for AssemblyLine events.
 void attachDebugger(int port, String host, boolean onerror)
          Attach a debugger to the AssemblyLine.
 void detachDebugger(Object msg)
          Detach the current debugger from the AssemblyLine.
 boolean getComponentDebugMode(String componentName)
          Query the debug mode setting of the specified component (Connector or Function Component).
 AssemblyLineConfig getConfig()
          Returns configuration information about the AssemblyLine.
 ConfigInstance getConfigInstance()
          Returns the configuration instance of the AssemblyLine.
 String getGlobalUniqueID()
          Returns AssemblyLine GUID.
 String getName()
          Returns the name of the AssemblyLine.
 String getNullBehavior()
          Gets the nullBehavior attribute of the AssemblyLine object
 String getNullBehaviorValue()
          Gets the nullBehaviorValue attribute of the AssemblyLine object.
 Entry getResult()
          This method returns the result entry object.
 TaskStatistics getStatistics()
          This method returns the TaskStatistics object for this AssemblyLine.
 String getSystemLog()
          Retrieves the current AssemblyLine's system log.
 String getSystemLogFileName()
          Returns the name of the log file of the AssemblyLine (not prefixed by folders path).
 String getSystemLogFilePath()
          Returns the fully-qualified path of the log file of the AssemblyLine.
 String getSystemLogLastChunk(int aLastKilobytes)
          Retrieves the last chunk from the current AssemblyLine's system log.
 int getUniqueCode()
          Returns the unique code of the AssemblyLine.
 boolean isActive()
          Checks if the AssemblyLine is active.
 boolean isSimulating()
          Check whether the AssemblyLine is simulating or not
 void removeListener(AssemblyLineListener listener)
           Unregister a listener for AssemblyLine events.
 void setComponentDebugMode(String componentName, boolean debug)
          Modify the debug mode setting of the specified component (Connector or Function Component).
 void setSimulating(boolean simulate)
          Changes the way the AssemblyLine treats the target systems it is connecting/interacting to/with.
 void stop()
          Stops the execution of the AssemblyLine.
 void stop(boolean sync)
          Stops the execution of the AssemblyLine, and waits for it to stop.
 

Method Detail

getConfigInstance

ConfigInstance getConfigInstance()
                                 throws DIException
Returns the configuration instance of the AssemblyLine.

Example

 var mAssemblyLine = session.getAssemblyLines()[0];
 
 var mConfigInstance = mAssemblyLine.getConfigInstance();
 
 var configId = mConfigInstance.getConfigId();
 
 var aAssemblyLineName = "AssemblyLine";
 
 var assemblyLine = mConfigInstance.startAssemblyLine(aAssemblyLineName);
 
 var objectName = com.ibm.di.api.jmx.mbeans.AssemblyLine.genObjectName(assemblyLine.getName(), assemblyLine.getUniqueCode());
 

Returns:
Returns ConfigInstance object representing the configuration instance of the AssemblyLine.
Throws:
DIException - if an error occurs while retrieving the configuration instance information.

getName

String getName()
               throws DIException
Returns the name of the AssemblyLine.

Example

 var mAssemblyLine = session.getAssemblyLines()[0];
 
 var mConfigInstance = mAssemblyLine.getConfigInstance();
 
 var configId = mConfigInstance.getConfigId();
 
 var aAssemblyLineName = "AssemblyLine";
 
 var assemblyLine = mConfigInstance.startAssemblyLine(aAssemblyLineName);
 
 var objectName = com.ibm.di.api.jmx.mbeans.AssemblyLine.genObjectName(assemblyLine.getName(), assemblyLine.getUniqueCode());
 

Returns:
String object representing the AssemblyLine’s name.
Throws:
DIException - if an error occurs while retrieving the name of the AssemblyLine.

getUniqueCode

int getUniqueCode()
                  throws DIException
Returns the unique code of the AssemblyLine.

Example

 var mAssemblyLine = session.getAssemblyLines()[0];
 
 var mConfigInstance = mAssemblyLine.getConfigInstance();
 
 var configId = mConfigInstance.getConfigId();
 
 var aAssemblyLineName = "AssemblyLine";
 
 var assemblyLine = mConfigInstance.startAssemblyLine(aAssemblyLineName);
 
 var objectName = com.ibm.di.api.jmx.mbeans.AssemblyLine.genObjectName(assemblyLine.getName(), assemblyLine.getUniqueCode());
 

Returns:
int value representing the unique code of the AssemblyLine.
Throws:
DIException - if an error occurs while retrieving the unique code of the AssemblyLine.

getConfig

AssemblyLineConfig getConfig()
                             throws DIException
Returns configuration information about the AssemblyLine.

Returns:
AssemblyLineConfig representing the configuration information of the AssemblyLine.
Throws:
DIException - if an error occurs while retrieving the configuration information of the AssemblyLine.

getNullBehavior

String getNullBehavior()
                       throws DIException
Gets the nullBehavior attribute of the AssemblyLine object

Returns:
String object representing the nullBehavior attribute value or null if no setting values are available for the AssemblyLine.
Throws:
DIException - if an error occurs while getting the nullBehavior attribute.

getNullBehaviorValue

String getNullBehaviorValue()
                            throws DIException
Gets the nullBehaviorValue attribute of the AssemblyLine object.

Returns:
String object representing the nullBehaviorValue attribute value or null if no setting values are available for the AssemblyLine.
Throws:
DIException - if an error occurs while getting the nullBehaviorValue attribute.

getStatistics

TaskStatistics getStatistics()
                             throws DIException
This method returns the TaskStatistics object for this AssemblyLine.

Example

 var runningALs = null;
 var stats = null;
 var result = null;
 var runningConfigs = session.getConfigInstances();
 for (var i = 0; i < runningConfigs.length; i++) {
        runningALs = runningConfigs[i].getAssemblyLines();
        for (var j = 0; j < runningALs.length; j++) {
                if (runningALs[j].isActive()) {
                        stats = runningALs[j].getStatistics().toString();
                        main.logmsg("statistics[" + j + "] = " + stats);
 
                        result = runningALs[j].getResult();
 
                        var attr = new com.ibm.di.entry.Attribute("LogURL", "/log/" + runningALs[j].getGlobalUniqueID());
 
                        runningALs[j].stop();
                }
        }
 }
 

Returns:
The accumulated TaskStatistics object.
Throws:
DIException - if an error occurs while getting the AssemblyLine statistics.

isActive

boolean isActive()
                 throws DIException
Checks if the AssemblyLine is active.

Example

 var runningALs = null;
 var stats = null;
 var result = null;
 var runningConfigs = session.getConfigInstances();
 for (var i = 0; i < runningConfigs.length; i++) {
        runningALs = runningConfigs[i].getAssemblyLines();
        for (var j = 0; j < runningALs.length; j++) {
                if (runningALs[j].isActive()) {
                        stats = runningALs[j].getStatistics().toString();
                        main.logmsg("statistics[" + j + "] = " + stats);
 
                        result = runningALs[j].getResult();
 
                        var attr = new com.ibm.di.entry.Attribute("LogURL", "/log/" + runningALs[j].getGlobalUniqueID());
 
                        runningALs[j].stop();
                }
        }
 }
 

Returns:
true if the AssemblyLine’s thread is alive, false otherwise.
Throws:
DIException - if an error occurs while getting the AssemblyLine state.

getResult

Entry getResult()
                throws DIException
This method returns the result entry object. This object is a copy of the working entry as it were when the AssemblyLine finished processing the connectors.

Example

 var runningALs = null;
 var stats = null;
 var result = null;
 var runningConfigs = session.getConfigInstances();
 for (var i = 0; i < runningConfigs.length; i++) {
        runningALs = runningConfigs[i].getAssemblyLines();
        for (var j = 0; j < runningALs.length; j++) {
                if (runningALs[j].isActive()) {
                        stats = runningALs[j].getStatistics().toString();
                        main.logmsg("statistics[" + j + "] = " + stats);
 
                        result = runningALs[j].getResult();
 
                        var attr = new com.ibm.di.entry.Attribute("LogURL", "/log/" + runningALs[j].getGlobalUniqueID());
 
                        runningALs[j].stop();
                }
        }
 }
 

Returns:
The last "work" entry object.
Throws:
DIException - if an error occurs while getting the result Entry.

stop

void stop()
          throws DIException
Stops the execution of the AssemblyLine.

Example

 var runningALs = null;
 var stats = null;
 var result = null;
 var runningConfigs = session.getConfigInstances();
 for (var i = 0; i < runningConfigs.length; i++) {
        runningALs = runningConfigs[i].getAssemblyLines();
        for (var j = 0; j < runningALs.length; j++) {
                if (runningALs[j].isActive()) {
                        stats = runningALs[j].getStatistics().toString();
                        main.logmsg("statistics[" + j + "] = " + stats);
 
                        result = runningALs[j].getResult();
 
                        var attr = new com.ibm.di.entry.Attribute("LogURL", "/log/" + runningALs[j].getGlobalUniqueID());
 
                        runningALs[j].stop();
                }
        }
 }
 

Throws:
DIException - if an error occurs while stopping the AssemblyLine.

stop

void stop(boolean sync)
          throws DIException
Stops the execution of the AssemblyLine, and waits for it to stop.

Example

 var stats = null;
 var runningConfigs = session.getConfigInstances();
 for (var i = 0; i < runningConfigs.length; i++) {
        var runningALs = runningConfigs[i].getAssemblyLines();
        for (var j = 0; j < runningALs.length; j++) {
                if (runningALs[j].isActive()) {
                        main.logmsg("Stopping [" + j + "]: " + runningALs[j].getName());
 
                        runningALs[j].stop(false);
 
                        stats = runningALs[j].getStatistics().toString();
                        main.logmsg("statistics[" + j + "] = " + stats);
                }
        }
 }
 

Parameters:
sync - If true, create a new Thread to do the waiting.
Throws:
DIException - if an error occurs while stopping the AssemblyLine.
Since:
7.1

getSystemLogFilePath

String getSystemLogFilePath()
                            throws DIException
Returns the fully-qualified path of the log file of the AssemblyLine.

Returns:
the fully-qualified log file path.
Throws:
DIException - if an error occurs while obtaining AssemblyLine log file path.

getSystemLogFileName

String getSystemLogFileName()
                            throws DIException
Returns the name of the log file of the AssemblyLine (not prefixed by folders path).

Returns:
the log file name.
Throws:
DIException - if an error occurs while obtaining AssemblyLine log file name.

getSystemLog

String getSystemLog()
                    throws DIException
Retrieves the current AssemblyLine's system log.

Returns:
the log generated by the AssemblyLine so far.
Throws:
DIException - if an error occurs while obtaining AssemblyLine's log.

getSystemLogLastChunk

String getSystemLogLastChunk(int aLastKilobytes)
                             throws DIException
Retrieves the last chunk from the current AssemblyLine's system log.

Parameters:
aLastKilobytes - Specifies in kilobytes the size of the log's last chunk that will be read.
Returns:
the last chunk of the AssemblyLine's log, generated so far.
Throws:
DIException - if an error occurs while obtaining AssemblyLine's log.

getGlobalUniqueID

String getGlobalUniqueID()
                         throws DIException
Returns AssemblyLine GUID. The GUID is a string value that is unique for each component ever created by a particular TDI Server.

Example

 var runningALs = null;
 var stats = null;
 var result = null;
 var runningConfigs = session.getConfigInstances();
 for (var i = 0; i < runningConfigs.length; i++) {
        runningALs = runningConfigs[i].getAssemblyLines();
        for (var j = 0; j < runningALs.length; j++) {
                if (runningALs[j].isActive()) {
                        stats = runningALs[j].getStatistics().toString();
                        main.logmsg("statistics[" + j + "] = " + stats);
 
                        result = runningALs[j].getResult();
 
                        var attr = new com.ibm.di.entry.Attribute("LogURL", "/log/" + runningALs[j].getGlobalUniqueID());
 
                        runningALs[j].stop();
                }
        }
 }
 

Returns:
The AssemblyLine GUID value.
Throws:
DIException - if an error occurs while obtaining the AssemblyLine GUID value.

isSimulating

boolean isSimulating()
                     throws DIException
Check whether the AssemblyLine is simulating or not

Returns:
true if the AssemblyLine is simulating, false if it is not.
Throws:
DIException - if an error occurs while obtaining the simulation state

setSimulating

void setSimulating(boolean simulate)
                   throws DIException
Changes the way the AssemblyLine treats the target systems it is connecting/interacting to/with. Turning the simulation on will make the AssemblyLine use the SimulationConfig child of the AssemblyLineConfig in order to properly handle sensitive data.

Parameters:
simulate - true switches the simulation on, false switches it off
Throws:
DIException - if an error occurs while changing the simulation state

addListener

void addListener(AssemblyLineListener listener,
                 boolean getLogs,
                 boolean getEntryOnEachCycle)
                 throws DIException
Register a listener for AssemblyLine events. You must be admin to execute this method. Beware that there is no automatic removal of orphaned listeners.

Parameters:
listener - Listener for AssemblyLine events.
getLogs - If true, the listener will receive logged messages.
getEntryOnEachCycle - If true the listener will receive the current entry at each AssemblyLine cycle's end.
Throws:
DIException - If the listener cannot be registered.
Since:
7.0
See Also:
removeListener(AssemblyLineListener)

removeListener

void removeListener(AssemblyLineListener listener)
                    throws DIException

Unregister a listener for AssemblyLine events. You must be admin to execute this method. Listeners are associated with the API object, not with the AssemblyLine in the Server, so you can remove only listeners added with the #addListener(AssemblyLineListener, boolean) method on the same object.

Beware that the listener may get notified one more time after it was unregistered. The only way to ensure this does not happen is to unregister the listener in one of its callback methods.

Parameters:
listener - The listener that needs to be removed.
Throws:
DIException - If the listener cannot be unregistered.
Since:
7.0
See Also:
#addListener(AssemblyLineListener, boolean)

attachDebugger

void attachDebugger(int port,
                    String host,
                    boolean onerror)
                    throws DIException
Attach a debugger to the AssemblyLine. You must be admin to execute this method.

Parameters:
port - Port of the debugger.
host - Host of the debugger.
onerror - If true breakpoints are disabled except when there is an error.
Throws:
DIException - If the AssemblyLine is already being debugged or the AssemblyLine cannot connect to the debugger.
Since:
7.0

detachDebugger

void detachDebugger(Object msg)
                    throws DIException
Detach the current debugger from the AssemblyLine. You must be admin to execute this method.

Parameters:
msg - This object will be sent to the debugger before the detaching occurs. Must be serializable. If null, nothing will be sent.
Throws:
DIException - If an error occurs while detaching the debugger.
Since:
7.0

getComponentDebugMode

boolean getComponentDebugMode(String componentName)
                              throws DIException
Query the debug mode setting of the specified component (Connector or Function Component). You must be admin to execute this method. A component will log debug level messages only if it is in debug mode. You can find out the names of the AssemblyLine components from the configuration - getConfig().

Parameters:
componentName - The name of a Connector or a Function Component from this AssemblyLine. Must be spelled exactly as it appears in the configuration.
Returns:
The debug mode of the component.
Throws:
DIException - If an error occurs while querying the debug mode.
Since:
7.0

setComponentDebugMode

void setComponentDebugMode(String componentName,
                           boolean debug)
                           throws DIException
Modify the debug mode setting of the specified component (Connector or Function Component). You must be admin to execute this method. Modifications are done on the fly and are not persisted in the configuration - getConfig(). If you run the same AssemblyLine again it will use the settings from the configuration.

Parameters:
componentName - The name of a Connector or a Function Component from this AssemblyLine.
debug - The new debug mode of the component.
Throws:
DIException - If an error occurs while setting the debug mode.
Since:
7.0
See Also:
getComponentDebugMode(String)